Secure facilities may require documented acoustic performance to support approved speech privacy requirements. OSAT provides independent field acoustic measurements for SCIFs, SAPFs and secure meeting spaces, with the measurement objective and acceptance criteria defined by the responsible authority.
Distinguish the required evidence
Sound isolation, speech intelligibility and speech privacy are related but distinct concepts. A room’s laboratory STC rating is not proof of its installed acoustic performance or operational confidentiality. The approved security specification determines which field evidence is required. See Sound Groups and NIC versus STC.
Speech privacy references and limitations
ASTM E2638 addresses privacy afforded by enclosed rooms for unaided listening under defined conditions; it does not prescribe a universal acceptance threshold or evaluate deliberate technical collection. It is not a replacement for approved SCIF acoustic criteria. IEC 60268-16 describes STI measurement and prediction methods, with application-dependent limitations.
Secure meeting and conferencing spaces
OSAT can discuss the appropriate independent acoustic evaluation for secure meeting rooms and video teleconferencing environments. See secure conference room testing and ICD 705 acoustic requirements. Scope and report handling must be coordinated through authorized project representatives.
Independent measurement and reporting
The report should clearly identify the commissioned measurement, reported descriptor, applicable criterion and limitations. No acoustic test by itself establishes accreditation or a guarantee against eavesdropping. For examples of OSAT’s published work, see project experience and case studies.
Discuss the required testing
For ordinary commercial environments, OSAT also provides commercial speech privacy testing. For secure-facility work, request an initial scope discussion using unclassified general information only.